2. ELECTRICAL CONNECTION REQUIREMENTS

This appliance must be properly installed and
grounded by a qualified technician in accordance
with the National Electrical Code ANSI/NFPA No.
70 -- latest edition -- and Local Electrical Code
requirements.
This appliance may be connected by means of
"permanent wiring" or power supply cord kit."
When installing permanent wiring, do not leave
excess wire in range compartment. Excess wire
in the range compartment may not allow the
rear access cover to be replaced properly and
could create a potential electrical hazard if wires
become pinched. Connect only as instructed under
"Permanent Wire Connections" in Step 4c. When
using flexible conduit or range cable use flex
connector or range cable strain relief.
2.1 Electrical Connection Requirements (U.S.A. only)
This appliance must be properly installed and
grounded by a qualified technician in accordance
with the National Electrical Code ANSI/NFPA
No. 70-latest edition- and local electrical code
requirements.
This appliance may be connected by means of
permanent "Hard Wiring" or "Power Supply Cord
Kit."
When hard wiring, do not leave excess wire in
range compartment. Excess wire in the range
compartment may not allow the access cover to
be replaced properly, and could create a potential
electrical hazard if wires become pinched. When
using flexible conduit or range cable, use flex
connector or range cable strain relief.
NOTE: Only use copper wire in connection to
terminal block.
Terminal
Block
2.2 Models Requiring Power Supply Cord Kit
Figure 7B –
3-Wire Cord Kit
The user is responsible for connecting the power
supply cord to the connection block located
behind the back panel access cover.
This appliance may be connected by means of
permanent "hard wiring"; flexible armored or
nonmetallic shielded copper cable (when local
code allow it) or by means of a power supply cord
kit.
NOTE: Electric slide-in range is shipped from
factory with 1 1/8" (2.9 cm) dia. hole as shown
on figure 9. If a larger hole is required, punch out
the knockout.
WARNING!
Risk of fire or electrical shock exists if an
incorrect size range cord kit is used, the
Installation Instructions are not followed,
or the strain relief bracket is discarded.
For mobile homes, new installation or
recreational vehicles, use only a power
cord kit design for a range at 125V /250V
50A recommended (minimum 40A). Cord
must have either 3 (when local code
permits grounding through neutral) or 4
conductors. Terminal on end of wires must
be either closed loop or open spade lug
with upturned ends. Cord must have strain-
relief clamp. If a 50A circuit is used, a 50A
power cord must be used.
CAUTION!
Do not loosen the nuts which secure the
factory-installed range wiring to terminal
block while connecting range. Electrical
failure or loss of electrical connection may
occur.
WARNING!
Electrical Shock Hazard
Electrical ground is required on this
appliance.
Do not connect to the electrical
supply until appliance is permanently
grounded.
Disconnect power to the circuit breaker
or fuse box before making the electrical
connection.
This appliance must be connected to a
grounded, metallic, permanent wiring
system, or a grounding connector
should be connected to the grounding
terminal or wire lead on the appliance.
Failure to do any of the above could result
in a fire, personal injury or electrical
shock.