Direct Electrical Connection to the Circuit
Breaker, Fuse Box or Junction Box
If the appliance is connected directly to the
circuit breaker, fuse box or junction box, use
flexible, armored or nonmetallic sheathed copper
cable (with grounding wire). Supply a U.L. listed
strain-relief at each end of the cable. At the
appliance end, the cable goes through the Direct
Connection Hole (see Figure 9) on the Cord
Mounting Plate. Wire sizes (copper wire only) and
connections must conform to the rating of the
appliance.
Where local codes permit connecting the
appliance-grounding conductor to the neutral
(white) wire (see Figure 10):
1. Be sure that no power is supplied on the cable
from residence.
2. Follow instructions on previous page for Four
Conductor Wire Connection to Range (Fig. 9).
3. In the circuit breaker, fuse box or junction box
(Fig. 10):
a) Connect the green (or bare copper) wire,
the white appliance cable wire, and the neutral
(white) wire together.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
Cable from Residence
Neutral
(white) Wire
Red
Wires
Green
(or Bare
Copper) Wire
Cable from
Appliance
NOTE: Be sure to
connect the supplied
ground strap to the
terminal block.
Figure 10
3-Wire (Grounded Neutral) Electrical
System (Example: Junction Box)
Black
Wires
Junction
Box
White Wire
U.L.-listed Conduit
Connector (or CSA
listed)
Where local codes DO NOT permit connecting
the appliance-grounding conductor to the neutral
(white) wire, or if connecting to 4-wire electrical
system (see Figure 11):
1. Be sure that no power is supplied on the cable
from residence.
2. Follow instructions on previous page for Four
Conductor Wire Connection to Range (Fig. 9).
3. In the circuit breaker, fuse box or junction box
(Fig. 11):
a) Connect the white appliance cable wire to
the neutral (white) wire.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper)
grounding wire to the grounding wire of the
circuit breaker, fuse box or junction box.
Cable from
Residence
Green (or Bare
Copper) Wire
Red
Wires
Green (or
Bare Copper)
Wire
Junction
Box
Cable from
Appliance
NOTE: Be sure to
remove the supplied
grounding strap.
Figure 11
4-Wire Electrical System
(Example: Junction Box)
White Wire
Black
Wires
White Wire
U.L.-listed Conduit
Connector (or CSA
listed)