NEVER use the device without the protective device of the machine.
For safe working use devices such as protective and pressure equipment, stop plate, feed
slide, etc.!
Faults in the machine, including the protective device or the saw blades, must be reported as
soon as they are detected and rectified immediately.
Circular saws must not be used for slitting, e.g. to finish a groove in the workpiece.
Folding or grooving is only permitted with a suitable protective device, e. g. a tunnel protective
device above the sawing table.
Support large panels to reduce the risk of kickback from a jamming saw blade. Large panels
can bend under their own weight. Panels must be supported on both sides, both near the saw
gap and at the edge.
Do not remove chips or splinters while the machine is running.
Worn table liners must be replaced in good time.
Do not use saw blades that are damaged or deformed.
The base body of the saw blade must not be thicker and the set must not be smaller than the
thickness of the riving knife. The riving knife must not be removed.
Always select a saw blade suitable for the material to be cut.
Saw blades that do not correspond to the characteristics in these instructions for use must not
be used.
Do not use tools that comply with EN 847-1.
Saw blades made of high-speed steel must not be used.
The tools must be transported and stored in a suitable container.
The maximum speed indicated on the saw blade must be maintained.
The circular table saw may only be transported with the transport lock on the handle engaged.
The upper protective hood must not be used as a handle for transportation.
During transport of the machine, the upper protective hood must cover the upper part of the
saw.
To minimize noise, the tool must be sharpened and all noise reduction elements (covers, etc.)
must be properly adjusted.
Maintenance
The plug must ALWAYS be disconnected from the socket
Always perform a visual inspection before use to determine if the equipment, and in particular
the power cord and plug, are damaged.
The device must not be used if it is damaged or the safety devices are defective.
If the device is defective, the repair must be carried out exclusively by the manufacturer's cus-
tomer service or by an authorised service partner. Only original accessories and original spare
parts may be used.
Only a regularly maintained and well-maintained device can be a satisfactory aid. Defects in
maintenance and care can lead to unforeseeable accidents and injuries.
The machine and in particular the ventilation slots must always be kept clean. Acidify the chip
ejection and/or dust extraction regularly.
Treat all moving parts with an environmentally friendly oil.