Remote control functions
7.4

Holiday mode

► Press
► Set the duration using the
► Press
► Press
automatically if not used for one minute (RM-2 Wireless: 30
seconds)
► Exit holiday mode
– Ends automatically after the time period
– Manual deactivation:
► Press the holiday key, "OFF" will appear in the display
► Press
Symbol Function
7.5
Interaction between the RM-2 and the heating control
unit
The set temperature and the actual room temperature have different
effects depending on how the system controller (BM/BM-2) is
configured.
– Weather-compensated control unit:
Actual room temperature has no effect on the control unit, as it
is simply a weather-compensated unit. Any change to the set
temperature (±4) has a direct effect on the heating curve of the
system controller.
– Room influence / room controller only:
The actual room temperature and the set temperature are used
for flow temperature control purposes. The absolute set room
temperature can be set as the "Day temperature" on the system
controller. The day temperature can be changed by ±4K by
adjusting the set value correction on the RM-2.
28 | WOLF GmbH
key in the standard display
to enter and confirm
to cancel. The RM-2 will also return to the menu
to confirm
Holiday mode: Economy/reduced operation mode
(heating and DHW) for a predefined period (15 min. to 99
days)
keys (15 minutes – 99 days)
+ +
-
-
3066510_202108