Figure 2 – Drawing of the installation holes
Mark on the wall and drill 2 holes with diameter ø8,
at a distance of 140 mm between them.
Place the plastic wall plugs in the holes drilled in
the wall.
Tighten the screws in the wall plugs.
Hang the range hood on the screws and tighten
them fully.
Connect the flexible aluminium pipe to the outlet
of the range hood and to the chimney, taking into
account that the bends and curves reduce the
absorption power, so they should be reduced to the
minimum.
Ensure that the connection will not get loose when
the appliance operates at maximum power.
Install the chimney bodies, mark and drill 2 holes
with diameter ø6 to install the hook for fixing the
chimney bodies.
Fix the chimney bodies with screws 3.9х9.5
Figure 3 – Sequence of installation of the components
English
RISK OF ELECTRIC SHOCK!
Do not bend or crush the power cord during
installation! Otherwise the cord may get damaged.
RISK OF INJURY!
There is risk of injury during installation because
of the sharp edges. During installation always use
protective gloves.
All safety bolts and safety covers shall be installed in the
way specified in the instructions, otherwise the appliance
may fall.
OPERATION OF THE RANGE HOOD
The accessible parts may get hot while the
appliance is operating in combination with
operating hot plates under it.
Using range hood model CH 200 60 IX
Range hood CH 200 60 IX is operated by two sliders
located on its lower panel. The left slider is for switching
on/off the lightening, and the right one is for controlling
the ventilation speed. The sliders should be moved
rightwards until the desired function is reached.
Switching off is done by moving the sliders back to their
leftmost position.
Figure 4 – Control buttons of CH 200 60 IX
Description of the sliders shown in figure 4:
Slider for control of the lightening:
Position 0 – lightening is off
Position I – lightening is on
Slider for control of the ventilation speed:
Position 0 – ventilation is off
Position 1 – 1st ventilation speed
Position 2 – 2nd ventilation speed
Position 3 – 3rd ventilation speed
Using range hood CH 202 60 WH and CH 301 60 IX
CH 202 60 WH and CH 301 60 IX range hoods are operated
by five round buttons located on the front panel for
comfortable and easy access. The rightmost button is for
switching on/off the lightening, and the remaining four
buttons are for control of the ventilation speed.
Figure 5 – Control buttons of CH 202 60 WH