Troubleshooting - Hellenbrand AQUA Systems SmartChoice Gen II O3 Installation, Operation And Service Manual

Eradicator with eog ii ozone
Table of Contents

Advertisement

Eradicator Gen II O
Gen II O

Troubleshooting

Condition
No Air in Tank
No Air in Tank
No Air in Tank
Not producing Ozone
Not Producing Ozone
Not Producing Ozone
Not Producing Ozone
Not Producing Ozone
Water in CD Tube
This guide above is intended to be a general idea generator for sourcing a trouble issue. There
could be additional possibilities. If the technician is not able to detect an issue that is prevent-
ing the system from functioning as designed, contact Aqua SystemsTech Support for additional
guidance @ 800-272-5511.
20
with Ozone
3
Possible Cause
Place control in Regeneration DN / Draw. Check for
Unit Not Drawing Air
draw at injector port
Unit drawing air, not pulling
Remove air intake filter and check for vacuum at tubing
through brine elbow
end while control is in Regeneration DN / Draw
Review programming sequence and cycle times with
Unit not programmed correctly
chart
Check Status light to confirm solid green light when the
Electrical Circuit Issue
EOG II is activated. if not, refer to status parameters on
page 16 to diagnose
Review that all wiring connections are correct with
Electrical Circuit Issue
diagram on page 16
Place unit in cycle and wait for relay 1 to activate. The
EOG II generator will turn on when Relay 1 activates.
Relay 1 not programmed
The EOG II status light will glow solid green if the
generator is active
CD Tube needs cleaned
Perform a test on the CD tube as explained on page 22 Clean CD tube or replace with clean tested tube
Cell is plugged with build-up
of nitrous byproducts and
Perform a test on the CD tube as explained on page 22 Clean CD tube or replace with clean tested tube
particulate matter.
Remove tygon tubing from the check valve side (flat
Ozone resistant check valve is
side) away from brine elbow while stepping valve
not seated or defective
through cycles. No water should escape the end of the
end of the check valve
Copyright ©2021 Aqua Systems, All Rights Reserved • 404 Moravian Valley Road, Waunakee, WI 53597
3
Install & Service Guide
Testing
Clean or replace internal valve parts, seal kit,
injector, piston. Increase feed pressure to filter.
Clean or replace ozone resistant check valve
Adjust programming
Correct improper or loose connections
Correct any wire out of place
Program accordingly
Replace ozone resistant check valve, then clean
and thoroughly dry CD tube, then re-attach tube
and put back into service; see pages 18-19
Manual Supplement
Solutions