Led Diagnostic Functions - Hellenbrand AQUA Systems SmartChoice Gen II O3 Installation, Operation And Service Manual

Eradicator with eog ii ozone
Table of Contents

Advertisement

Eradicator Gen II O
Gen II O
Wiring Diagram
Ozone Components Wiring Guide
The EOG II comes pre-assembled, wired, and is ready to connect to the Eradicator control.
See the wire harness connection instructions to the conrol valve on page 9.
The following diagram can be used for future service and trouble shooting if necessary.

LED Diagnostic Functions:

Green Light Blinking Slowly: Standby mode; unit is powered, pilot input is OFF.
Green Light Blinking Quickly: High voltage startup (up to 3 seconds).
Green Light Solid: High voltage is ON & stable; CD cell producing ozone.
Red Light Solid: Unstable operation; CD cell may need cleaning.
Green/Red Light Alternating Twice/Second: HV is ON, but
operating current is low. If persistent, CD cell may need cleaning.
Red Light Flashing: NO or NC contacts are shorted. Remove short condition.
Orange Light: 1-year timer has expired; clean CD cell, then reset timer by pressing red "alarm reset" button on PCB
once.
16
with Ozone
3
Connect to
Control Valve
To Relay 1
terminal on
Control Valve
Circuit Board
To Power
Terminal on
Control Valve
Circuit Board
Copyright ©2021 Aqua Systems, All Rights Reserved • 404 Moravian Valley Road, Waunakee, WI 53597
3
Install & Service Guide
Power
Input
Ozone
Outlet
Diagnostic
LED
GND
Terminal
PILOT
Block
GND
N.O.
N.C.
Air Inlet
Harness to
Control Valve
Manual Supplement
Alarm
Reset
CD
Cell
WARNING
!
ELECTRICAL
HAZARD
+
DISCONNECT POWER
BEFORE SERVICING
+
Not Shown:
Safety Cover

Advertisement

Table of Contents
loading

Table of Contents