Specifications; Table 5: Electrical Sampling Modules - Signal Acquisition - Tektronix 80E07 User Manual

Electrical sampling remote modules
Table of Contents

Advertisement

Specifications

80E07, 80E08, 80E09, and 80E10 User Manual
This section contains specifications for the 80E07, 80E08, 80E09, and 80E10
remote sampling modules. All specifications are guaranteed unless noted as
"typical." Typical specifications are provided for your convenience but are not
guaranteed. Specifications that are marked with the n symbol are checked in
Performance Verification procedures provided in the Specifications and
Performance Verification manual for your main instrument.
All specifications apply to all models of sampling module unless noted
otherwise. To meet specifications, these conditions must first be met:
H The instrument must have been calibrated/adjusted at an ambient tempera-
ture between +20 _C and +30 _C.
H The instrument must have been operating continuously for 20 minutes within
the operating temperature range specified.
H The instrument must be in an environment with temperature, altitude,
humidity, and vibration within the operating limits described in these
specifications
H A compensation must have been performed. Recompensation is required if a
module is moved to another compartment.

Table 5: Electrical sampling modules - Signal acquisition

Specifications
Real time accessory interface
Extender accommodation
Number of input channels
Input connector
80E07 and 80E08
80E09 and 80E10
n Input impedance
Vertical dynamic range,
non-clipping
1
Vertical operating range
,
maximum
2
Vertical nondestruct range
,
maximum input voltage
Vertical number of digitized bits
Characteristics
Tekprobe- - SMA interface is provided through the electrical
sampling-module interface, one per vertical channel.
Module extenders (015-1568-xx, 015-1569-xx, 80N01, and
80A03) are not permitted and are mechanically blocked from
being used in front of the main module.
2
2.92 mm (K) female SMA-compatible connector
1.85 mm (V) female connector
50
1
1 V
(offset
500 mV)
pp
1.1 V
2.0 V (DC+peak AC)
14 bits full scale
49