Overview

The PSW Universal signal converter is used for connecting modern high-efficiency
pumps to controllers without a corresponding output. Due to its many adjustment
possibilities, almost any pump can be connected.
• No controller replacement required
• For solar and heating pumps
• Flexible in- and outputs: PWM, 0-10 V, 0-20 mA, 4-20 mA
• Inversion of the output signal possible
• Also usable as a PWM repeater
The PSW Universal pump signal converter converts the 230 V signal of the con-
troller to which a standard pump had previously been connected, into a signal that
enables speed control of a HE pump. 1 HE pump per signal converter connectable.
The following signal conversions are possible:
Output signal
PWM PWM
inv.
Input signal
x
x
On / Off
PWM
x
PWM inv.
x
0-20 mA
x
x
0-20 mA inv.
x
x
4-20 mA
x
x
4-20 mA inv.
x
x
0-10 V
x
x
0-10 V inv.
x
x
Burst / wave packet
x
x
Leading-edge phase
x
x
control
Trailing-edge phase
x
x
control
Not suitable for heat pumps and DHW exchange controllers
0-20 mA 0-20 mA
4-20 mA 4-20 mA
0-10 V 0-10 V
inv.
inv.
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Technical data
Inputs: On / Off
PWM, 0-10 V, 0-20 mA, 4-20 mA, bursts / wave packet, lead-
,
ing-edge phase control, trailing-edge phase control
Outputs: semiconductor relay: 1, PWM: 1, other: 0-10 V, 0-20 mA, 4-20 mA
PWM frequency: 625 Hz ±1 %
PWM voltage: 11 V
Switching capacity: 1 (1) A 240 V~ (semiconductor relay)
Total switching capacity: 1A 240 V
Power supply: 100 – 240 V~ (50 – 60 Hz)
Supply connection: type X attachment
Power consumption <1W
Mode of operation: 1.Y
Rated impulse voltage: 2.5 kV
Functions: signal converter
Housing: plastic, PC-ABS and PMMA
inv.
Indication / Display: operating control LED
Mounting: wall mounting
x
x
Operation: 1 DIP switch, 1 selector switch
Ingress protection: IP 20 / EN 60529
x
x
Protection class: I
x
x
Ambient temperature: 0 ... 40 °C
x
x
Degree of pollution: 2
x
x
Humidity: 10 ... 90 %
x
x
Overvoltage category: 2
Fuse: T2A
x
x
Maximum altitude: 2000 m above MSL
x
Dimensions: 144 x 208 x 64
x
x
x
x
x
x