6 Check Point of Electronic Components

Before repairing, use multimeter to judge circuit stand of fail
No
Part
Electric
1
Filter
2
NTC
3
Capacitor
Drain
4
Pump
Picture
With a multimeter to test the
connection at both ends of the N and L.
Measured across the NTC with a
multimeter, the resistance line with RT
table.
Tested capacitance value should be 16 ±
5% uF.
Measure the ends of the pump with a
multimeter . 800× (1 ± 10%) Ω (20 ℃)
Test Description
.
parameters
250VAC 50/60HZ,
12A
10℃ 9.6±5%KΩ
15℃ 7.6±5%KΩ
25℃ 4.8±5%KΩ
30℃ 3.9±5%KΩ
16μF/450V
220-240V, 60HZ,
0.8m, 4L/min, 13W