The Drum Does Not Spin While The Control Panel Can Display - Midea MDC100-CH21B/B05E-US Service Manual

Tumble heat pump dryer
Table of Contents

Advertisement

5 Troubleshooting

5.2 The drum does not spin while the control panel can display

The drum does not spin but the
panel
control
can display
Y
The belt is loosened or
broken
N
The P0 terminal is not
insert
N
The door switch is
damaged
N
The wire components are
loose or damaged
N
The tension spring is off
or failure
N
The motor capacitor
terminal is not inserted
N
The front support wheel
is damaged
N
The motor damage
N
The drum is stuck by
something
N
The barrel axis is
damaged
Y
Reassemble or replace the belt
Y
Plug the terminal
Y
Replace door switch
Y
Insert or replace the wire
components
Y
Install or replace the tension spring
Y
Insert capacitor terminal
Y
Replace the front support wheel
Y
Replace the motor
Y
Check the drum and eliminate
Y
Replace the drum