E50 Led Is Lighting After The Cycle Finished(Only For Bldc Model); E60 Led Is Lighting After The Cycle Finished(Only For Bldc Model) - Midea MDC100-CH21B/B05E-US Service Manual

Tumble heat pump dryer
Table of Contents

Advertisement

5 Troubleshooting
5.9 E50 LED is lighting after the cycle finished.
5.10 E64 LED is lighting after the cycle finished(only for BLDC model)
The terminals of motor and control
The wire components are damaged
E50 LED is lighting
Y
Restart the dryer
N
Change the motor
E64 LED is lighting
Y
panel are loosened
N
N
Change the BLDC motor
Y
OK
Y
Plug in the terminals
Y
Replace the wire components
34