Download Print this page

Datamax H-Class GPI O Option Instructions Manual page 9

Advertisement

Failure t o properly configure t he GPI O Port can result in dam age t o t he print er and / or connect ed devices.
W ARN I N G
Pin
Sign a l N a m e / D ir e ct ion
1
+ 5 VDC
2
I nput 6
3
I nput 3
4
Out put 6
5
Out put 3
6
Ground
7
I nput 5
8
I nput 2
9
Out put 5
10
Out put 2
11
+ 24 VDC
12
I nput 4
13
I nput 1
14
Out put 4
15
Out put 1
[1]
Signal directions given relative to the printer.
[ 1]
Ju m pe r
Posit ion
I nst alled
JMP 11
Rem oved
N/ A
N/ A
N/ A
N/ A
I nst alled: Pins 1 – 2
JMP 7
I nst alled: Pins 2 – 3
Rem oved
I nst alled: Pins 1 – 2
JMP 4
I nst alled: Pins 2 – 3
Rem oved
I nst alled
JMP 10
Rem oved
N/ A
N/ A
N/ A
N/ A
I nst alled: Pins 1 – 2
JMP 6
I nst alled: Pins 2 – 3
Rem oved
I nst alled: Pins 1 – 2
JMP 3
I nst alled: Pins 2 – 3
Rem oved
N/ A
N/ A
N/ A
N/ A
N/ A
N/ A
I nst alled: Pins 1 – 2
JMP 5
I nst alled: Pins 2 – 3
Rem oved
I nst alled: Pins 1 – 2
JMP 2
I nst alled: Pins 2 – 3
Rem oved
GPI / O Por t B Ove r vie w
Print er + 5VDC is used ( .5 am p m axim um ) .
N ot e :
Drawing m ore t han .5 am ps can cause unreliable print er operat ion.
+ 5VDC m ust be supplied.
Program m ed input funct ion.
Program m ed input funct ion.
Program m ed out put funct ion pulled- up t o + 5VDC.
Program m ed out put funct ion pulled- up t o + 24VDC.
An ext ernal volt age via ext ernal pull- ups will det erm ine t his level, not exceed + 30VDC.
Program m ed out put funct ion pulled- up t o + 5VDC.
Program m ed out put funct ion pulled- up t o + 24VDC.
An ext ernal volt age via ext ernal pull- ups will det erm ine t his level, not exceed + 30VDC.
Print er chassis is used.
Ground m ust be supplied.
Program m ed input funct ion.
Program m ed input funct ion.
Program m ed out put funct ion pulled- up t o + 5VDC.
Program m ed out put funct ion pulled- up t o + 24VDC.
An ext ernal volt age via ext ernal pull- ups will det erm ine t his level, not exceed + 30VDC.
Program m ed out put funct ion pulled- up t o + 5VDC.
Program m ed out put funct ion pulled- up t o + 24VDC.
An ext ernal volt age via ext ernal pull- ups will det erm ine t his level, not exceed + 30VDC.
Print er + 24 VDC ( 1.5 am p m axim um ) .
Program m ed input funct ion.
Program m ed input funct ion.
Program m ed out put funct ion pulled- up t o + 5VDC.
Program m ed out put funct ion pulled- up t o + 24VDC.
An ext ernal volt age via ext ernal pull- ups will det erm ine t his level, not exceed + 30VDC.
Program m ed out put funct ion pulled- up t o + 5VDC.
Program m ed out put funct ion pulled- up t o + 24VDC.
An ext ernal volt age via ext ernal pull- ups will det erm ine t his level, not exceed + 30VDC.
7
Fu n ct ion / D e scr ipt ion

Advertisement

loading