Destination setting
1. find the Setting Jumper and FUSE in the FL and FR 092 ICEPOWER250ASP.
2. Set the Jumper to the destination country voltage on both PCB's.
3. Replace the fuse value to the destination. T3.15A for 115 V and T2.5A for 230V.
4. Rewire the Jumper wire on the PCB 016 X-1438A01. Use J101 for 115V and J102 for 230V.
Setting Jumper for the Destination
115V or 230V on both PCB's
Using Fuses
T3.15 for 115V, T2.5A for 230V on both PCB's
6
RMB-1077