RB-1091

Destination setting

1. find the FUSE in the 092 ICEPOWER1000ASP.
2. Set the Fuse to the destination country voltage on the PCB.
3. Replace the fuse value to the destination. 5HT10-R for 115V and 5HT6.3 for 230V.
4. Rewire the Jumper wire on the PCB 016 X-1438A01. Use J101 for 115V and J102 for 230V.
Connecting Fuse 5HT6.3-R for 230V destination
Connecting Fuses 5HT10-R for 115V Destination