8
Technical manual
This section is for qualified technical personnel only!
8.1
Sifter and feeder testing
Turn the machine off.
Press and hold COOLING button and press START/PAUSE button once;
release COOLING button as you see St-S on the display.
Sifter testing Press and hold COOLING push button. The display will
show St-S message and sifter starts to rotate as long as the button is kept
pressed.
Feeder testing Press and release COOLING push button. The display
will show St-F message and feeder executes one feeding cycle.
8.2
Setup mode
There are two ways to enter the setup mode and change the parameters:
1. If machine is turned off, press and hold COOLING button and press
START/PAUSE button once; release COOLING button as you see
St-S on the display.
2. If machine is running (heating, popping, or cooling mode), press and
hold two temperature adjustment push buttons, the display shows
test, and when you see next reading, release the buttons. The read-
ing will be like P214 , where P represents the current stage of the
machine operation (it can be either H or C for heating or cooling
stage, respectively); and 214 is the current temperature in the cham-
ber.
Press START button to move through the parameters. Use temperature
adjustment push buttons to change the value of the parameter displayed.
19
Need help?
Do you have a question about the Robopop 75 and is the answer not in the manual?