4 .5 RC4 2 Ra t e Com pa ss
Dim ensions: ..................................................... See Figure 4- 4
Weight : .......................................................... 0,9 kg ( 2,0 lbs)
Mat er ial: ........................................................... Off- whit e ABS
Environm ent al Prot ect ion: ................................................ I P56
Tem perat ure r ange:
Supply and int erface: .................................... 8- 16V via Sim Net
Power consum pt ion: ...................................................... 0,9 W
Sim Net Net wor k load fact or ( NL) : .......................................... 2
Sim Net port s ( input / out put ) : ................................................ 1
Cable supplied: ............ 5.5 m ( 18') Sim Net cable wit h connect or
Mount ing: .................................................... Deck or bulkhead
Aut om at ic Perform ance:
St at ic Perform ance:
Dynam ic Perform ance:
Out put signal .......................................... PGN127250, 127251
NMEA2000 com pliant
26 | Technical specificat ions
Operat ion: ....................... 0 t o + 55 ° C ( + 32 t o + 130 ° F)
St orage: ........................ –30 t o + 70 ° C ( –22 t o + 158 ° F)
Calibrat ion: ...... Aut om at ically act ivat ed from cont rol head
Rat e offset : .............. Aut om at ically adj ust ed cont inuously
Dev iat ion cont r ol: .......................................... Aut om at ic
Heading out put : ............................ Rat e sensor st abilized
Roll/ Pit ch: ........................................................... ± 35°
Accuracy: ............................ ± 3 degrees aft er calibrat ion
Repeat abilit y: ..................................................... ± 1.0°
Wit h random excit at ion of ± 10° at m ax . 1 Hz:
Wit h heading st ep input of 90° at a rat e of 10° / s:
Heading error < 2°
Heading error 10 sec aft er t urn < 2°