Maintenance; Periodic Inspection, Cleaning; Operative Sequence; Power Source Controls And Signals - Cebora PLASMA PROF 123 ACC Service Manual

Power source
Table of Contents

Advertisement

CEBORA S.p.A.

3 - MAINTENANCE.

ANY INTERNAL INSPECTIONS OR REPAIRS MUST BE CARRIED OUT BY QUALIFIED
BEFORE BEGINNING MAINTENANCE OPERATIONS, UNPLUG THE MACHINE FROM
THE MAINS AND WAIT FOR THE INTERNAL CAPACITORS TO DISCHARGE

3.1 - Periodic inspection, cleaning.

Periodically remove dirt or dust from the internal parts of the Power Source, using a jet of
low-pressure dry compressed air or a brush.
Check the condition of the output terminals and power supply cables of the Power Source;
replace if damaged.
Check the condition of the internal power connections and connectors on the electronic
boards; if you find "loose" connections, tighten or replace the connectors.

3.2 - Operative sequence.

The following sequence reflects correct equipment operation. It may be used as a guiding
procedure for troubleshooting.
It must be carried out after each repair without any errors.

3.2.1 - Power Source controls and signals.

3.302.269
WARNINGS
PERSONNEL.