8.4 Serial Port Configuration

Example: AT#SER0LN=0<cr>
#SERn
NP=< T|U|L >
SM=<R|D|H|F >
LN=< 0|1 >
BR=<baud rate >
DB=< data bits > // 7, 8
PR=< N|O|E >
ST=< stop bits > // 1, 2
FL=< N|S|H >
SP=<listen network port number>
SD=<disconnect timeout in seconds>
SO=<override timeout in seconds>
CM=<N|P|R>
CI=<dest ip name/addr>
CP=<destination port number>
CD=<disconnect timeout in seconds>
CR=<retry timeout in seconds>
SBL2e Dual Serial-to-Ethernet User's Manual
Downloaded from
Elcodis.com
electronic components distributor
// n = serial port number, 0, 1
// network protocol T = tcp, U = udp, L = udp learn
// R=RS232, D=debug, H=Half duplex RS485, F=Full duplex RS485
// 1 = listen for connection 0= don‟t listen
// none, odd, even
// none, software or hardware
// outgoing connection mode: never (listen mode only),
power-up or upon received serial data