Description / explanation
Manifold design
The cross-section of the manifold must be at
least equal to the sum of the individual cross-
sections of the connected feed lines.
Lay the manifold with a continuous slope
>3 %.
Diameters of the connected lines
The minimum diameter of the feed line and
the drain line must be at least 1/2" (interior 
diameter at least 13 mm (0.5 in)).
Do not fit any reductions in the line (e.g. using 
reducing nipples or fittings).
Bypassing filters
Discharge each condensate collection point
with a separate BEKOMAT
Do not create any filter bypass points.
Ensure venting
If the slope in the inflow is not sufficient or 
there are other problems with the inflow, 
install a venting line.