Read Input Registers (0X04) - Beko BEKOMAT 12i Original Installation And Operation Manual

Table of Contents

Advertisement

Original installation and operation manual

3.5.3.1 Read Input Registers (0x04)

Modbus
Contents
address
1116
Main Timer Hi-Word
1117
Main Timer Lo-Word
1102
Main Counter Hi-Word
1103
Main Counter Lo-Word
1540
Temperature Hi-Word
1541
Temperature Lo-Word
1542
Temperature Hi-Word
1543
Temperature Lo-Word
1544
Voltage Hi-Word
1545
Voltage Lo-Word
1700
Status POWER LED
1701
Status ERROR LED
1702
Status Valve LED
1760
Main Button State
3103
Remaining Time Hi-Word
3104
Remaining Time Lo-Word
3105
Remaining Counts Hi-Word
3106
Remaining Counts Lo-Word
3200
Error Flags
3201
Error1 Flag
3202
Error2 Flag
3203
Error3 Flag
Description / explanation
Operating hours counter [h]
Counter for switching cycles
CPU temperature [°C]
CPU Temperature [°F]
Supply Voltage [V]
LED off = 0
LED 100 % = 1
LED 50 % = 2
LED off = 0
LED 100 % = 1
LED 50 % = 2
LED off = 0
LED 100 % = 1
LED 50 % = 2
Status TEST button
On = 1
Off = 0
Remaining service time [%]
Remaining switching cycles [%]
All Error Flags
Bit 1 = Error1 Flag
Bit 2 = Error2 Flag
Bit 3 = Error3 Flag
Bit 4 = Error4 Flag
Bit 5 = Error5 Flag
Bit 6 = Error6 Flag
Code Flash faulty
1 = Error active
0 = Error inactive
Configuration faulty
1 = Error active
0 = Error inactive
Device not adjusted
1 = Error active
0 = Error inactive
BEKOMAT
12i / 12i CO / 12i CO PN63
®
Data type
u32
u32
float
float
float
u16
u16
u16
u16
float
float
u16
u16
u16
u16
21 | 76

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bekomat 12i coBekomat 12i co pn63

Table of Contents