Removal of PCBs

3. Removal of PCBs
Procedure
Step
1. Remove the main PCB.
1
Remove the screw.
2
Unfasten the 2 hooks.
3
Lift up the main PCB.
20
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Main PCB
Points
(R6340)
(R6341)
(R16894)
Si00-776
Removal Procedure