Si00-776
Step
7
Disconnect the
connector for the
electronic expansion
valve coil [S20].
8
Disconnect the
connector for the
thermistors [S90].
9
Disconnect the
connector for the
overload protector (OL)
[S40].
Removal Procedure
Procedure
[S20]
[S90]
Outdoor temperature
Discharge pipe
thermistor, outdoor heat
thermistor
exchanger thermistor
[S40]
Removal of Electrical Box
Points
When reassembling, insert
the clamps of the thermistor
ASSY into the hole as below.
(R16893)
(R17101)
(R17102)
Thermistor
ASSY
(R17095)