Removal of PCBs

3. Removal of PCBs
Procedure
Step
1. Remove the main PCB.
1
Remove the cover of
the electrical box.
2
Remove the 3 screws.
3
Unfasten the 4 hooks.
Lift up the main PCB.
4
22
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Hook
Hook
Release the 4 hooks. The
hooks are marked with
(R14617)
Main PCB
(R10404)
(R10405)
(R10406)
Si12-995