Removal of PCBs
Step
4. Remove the display PCB.
1
Remove the filament
tape.
2
Remove the drip proof
cover.
3
Slightly lift the top
hooks to detach.
4
Undo the bottom hook
to remove the display
PCB.
24
Procedure
Filament
tape
Drip proof cover
Display PCB
Points
(R6355)
(R6356)
(R6357)
(R6358)
Removal Procedure