Both indicate flow totals in gallons and litres. • Local – The GG510 Pulse Out with Display requires the • The Pulse Out with Display can be used on all GPI GPI Conduit Connector Kit (Part #113437-01) for local models, including the Precision G series, the Industrial mounting to the G2 series meter.
Page 3
• Wall • Pipe • Meter (1 inch FNPT conduit connection required) Some products come with 20 feet of shielded cable. GPI offers an optional cable kit with 100 feet of cable (see spare parts list). When wiring longer lengths of cable, be sure to connect the shield to LOCAL-COM only! (Multiple shield connections may cause ground-loop problems.
Page 4
P O W E R S I G N A L I N P U T 9V Battery (included) Sine Wave (coil) 9V_BAT+ COIL_A Connect battery (included) red wire (+) to terminal. Connect either coil wire to terminal. COIL_B Connect battery (included) black wire (–) to any terminal.
Page 5
S I G N A L I N P U T S I G N A L O U T P U T Open Collector Open-Collector OC_OUT Connect signal wire to terminal. Connect ground wire to any terminal. HI-F_IN Connect signal wire to terminal.
Access to the configuration settings require a specific pro- to “0.00.” You can do this even while fluid is flowing, in which cedure and a pin code available through the GPI website at case counting will resume after you release the DISPLAY www.gpi.net or call GPI Customer Serivce at 888-996-3837.
A small propeller displays to indicate liquid is flowing through the meter. Calibration Curves The GPI electronics have enhanced calibration features. All calibration information is visible to the user as words in the upper part of the display, above the numeric digits.
Page 8
KF 01 (or KF 02, KF 03, to either enter a K-factor calibration may be used on the GPI GM series, or any other etc., if you are repeating this step). or exit calibration. If you want to exit the calibration positive displacement meter, with excellent results.
Page 9
Your Actions Notes Your Actions Notes 3. Once the buttons have been The computer is waiting 9. To enter another calibration point, released from Step 2, the display for you to make a decision go back and repeat Steps 3 will show the blinking message to either exit from field through 8.
“run ##” message will Replace the battery when the readout becomes dim or blank. increment each time you Replace the battery with a 9-volt lithium battery. Order GPI repeat the calibration part number 902006-44. process (run 01, run 02, run 03, etc., up to run 15).
Please contact GPI before returning any part. It may be possible to diagnose the trouble and find a solution with a telephone call. GPI can also inform you of any special require- ments you will need to follow for shipping.