4

PUSH BUTTONS

Quickly double click
Press for 2 seconds
Press for 3 seconds
Press for 5 seconds
ADJUSTMENTS & SETTINGS
1
VISIBLE SPOTS
Quickly press the push button twice to activate the visible spots, they will help you position the curtain.
front view
Do not look directly into the visible beams!
2
CURTAIN POSITION
Quickly double-click the push button within 1 second to show the visible spots, and then adjust the tilt angle
(range: 0 to +5°) with the screwdriver until the visible spots are at the correct position.
d
Recommended position for the visible spots:
If 2 m mounting height: d≥4cm
If 4 m mounting height: d≥6cm
to activate or deactivate the visible laser spots.
to launch a safety field teach-in process.
to confirm the setting after changing the DIP switch.
to acknowledge the 6x flashing error message and confirm that you want
the sensor to be mounted higher than 4m. Note that installation height
higher than 4m, the test body CA (EN16005) might not be detected.
If 3 m mounting height: d≥5cm
If 5 m mounting height: d≥7cm
top view
FACTORY VALUES
4