TECHNICAL SPECIFICATIONS

Technology
Detection mode
Max. installation height
Opening angle
Angular resolution
Testbody
Optical characteristics
IEC/EN 60825-1
Supply voltage
Power consumption
Response time
Output
LED-signals
Dimensions
Material - Colour
Tilt angles
Protection degree
Temperature range
Humidity
Vibrations
Conformity
BEA /
A-B Area, 3rd Floor, No.1 Building
LASER scanner, time-of-flight measurement
Presence
4m (with reflectivity of 5%)
5m (with reflectivity of 8%)
90°
0.23° (400 spots within 90°)
700 mm x 300 mm x 200 mm (test body CA according to EN 16005, <4m)
Wavelength 905 nm; average output power 0.05 mW; CLASS 1
Wavelength 650 nm; max. output CW power 3 mW (CLASS 2) - visible spot
12-24V DC ± 15%
≤ 2.2 W
Max. 90 ms
1 optocoupler ( galvanic isolation - polarity free )
Max. switching voltage: 42V AC/ 60V DC
Max. switching current: 100 mA
1 Relay ( free of potential change-over contact )
Max. contact voltage: 60V AC / 125V DC
Max. contact current: 1.0A ( resistive )
Max. switching power: 30W ( DC ) / 60VA ( AC )
1 bi-coloured LED: detection/output status
178 mm (L) × 85 mm (H) × 53 mm (D)
PC/ABS - Black
0° to +5°
IP54 (IEC/EN 60529)
-30°C to +60°C if powered
0-95 % non-condensing
< 2 G
EN 61000-4-3:2006 + A1:2008 + A2:2010
EN 61000-4-8:2010
EN 61000-4-16:2016
EN 61000-6-3:2007 + A1:2011
EN IEC 61000-6-2:2019
Specifications are subject to change without prior notice. All values are measured in specific conditions.
/
No.5 Xinghai Road, Beijing Economic Technological Development Area, Beijing
T
/ F
+86 10 57761630
+86 10 62628775
/ E
/ W
info-as@beasensors.com
asia.beasensors.com
/