INSTALLATION
1

DIP SWITCH

DIP 1 OUTPUT CONFIGURATION
DIP 2 ENVIRONMENT
DIP 3 BACKGROUND
DIP 4 MONITORING
DIP 5 WORK MODE
* When DIP2 is OFF (critical environments), testbody CA (EN 16005) might not be detected.
2

INSTALLATION OF THE SENSOR

Install the sensor at the right position and fix it with the screws.
3
WIRING
12-24 V DC
COM
*
NO
COM
*
NC
3
ON
NO/NC
standard
ON
active low
normal
After changing a DIP switch, the orange LED flashes.
A LONG push on the push button confirms the settings.
x
> 3 sec.
front side
recommended position
GREEN
+
POWER SUPPLY
BROWN
-
YELLOW
R1(RELAY)
WHITE
PINK
R2(OPTO)
GREY
RED
BLUE
** TEST / MONITOR
OFF
NO/NO
Switch to CRITICAL when external disturbances are
critical*
likely to cause unwanted detections.
Switch to OFF when there is no background
OFF
(e.g. glass floor).
active high
JFS
Make sure the front side of the sensor faces towards the
outside of the door.
Install the sensor in the canopy of the door above the
area to be protected by safety.
*
Output status when the sensor is operational
without detection.
The safety field responded relay will switches
automatically to output status with detection
during the remote control access.
**
Only the safety field responded relay would
respond for the test.