Resolving Load Errors

If the system inventory and number of racks of the session you're loading do not match the current configuration, SuperRack must
reconcile the mismatch before loading the session.
Example 1
The saved session has more racks than does the current SuperRack configuration.
Example 2
The I/O inventory of the saved session does not match the current inventory.
The Session Load routine provides two strategies when sessions and inventory are mismatched.
120
In this case, the new session calls for 64 racks, while the system inventory has
only 32. The session will load the first 32 racks and drop the last 32. This
structure becomes permanent when the user performs a save on the "reduced"
session—it cannot be undone. Make a copy ("Save As") before you save the
reduced session.
Whenever the saved session's I/O inventory is not the same as that of the
mixer, there is a chance that certain routes cannot be supported. If, for
example, the session calls for a 128-channel MADI device, while the current
I/O hardware in the same slot is an 8-channel I/O, it will be difficult to provide
the session with the I/O channels it needs.