17 INSTALLATION REQUIREMENTS &
RECOMMENDATIONS
1. IMPORTANT 1: TAKE CARE THE CONNECTOR COUNTERPARTS
(HEADER PINS AND RECEPTACLE CONTACTS) ARE CHEMICALLY
HOMOGENEUS.
EpsacW adopts a 23poles AMPSEAL header tin plated connector. So the
contacts in the counterpart must be tin plated too. In case a gold plated type
AMPSEAL connector will be used in the epsacW side, the contacts in the
counterpart must be gold plated too.
2. IMPORTANT 2: DO NOT CONNECT A LIVE BATTERY TO THE EPSACW
+B and –B CONNECTIONS. A live battery generates a conflict with the
discharged caps rail inside the epsacW: a consequent spark will damage
(meld) the pins of the connector. Keep the battery unplugged when
connecting the receptacle to its header counterpart.
3. IMPORTANT 3: TAKE CARE YOUR FINGERS STAYS AWAY FROM THE
PINS OF THE EPSACW CONNECTOR DURING INSTALLATION. The
fingers can bend or contaminate the pins.