What To Do If; No Power Generation; Fault" Is Displayed; Service" And Ë Are Displayed - Viessmann VITOVALOR PA2 Operating Instructions Manual

Fuel cell based micro chp unit as add-on appliance
Table of Contents

Advertisement

What to do if...

No power generation

Cause
Fuel cell module is out of operation as no heat transfer
through the heating circuits, heating water buffer cylin-
der or other cylinders is possible.
Fuel cell module in regeneration phase
"Power generation OFF" is selected.
The 5 year service interval has expired.
The 10 to 12 year service interval has expired.
The total service life of the fuel cell module (20 years)
has been exceeded.
Power export is briefly interrupted.

"Fault" is displayed

Cause
System fault
"Service" and
ë
Cause
The time for a service as specified by your contractor
has arrived.

"Panel locked" is displayed

Cause
The control panel is locked.

System characteristics during a mains fault

Mains faults can have an adverse effect on the charac-
teristics of the system.
In case of a mains fault (e.g. power cut), the mains
monitor (ENS) of the system automatically disconnects
it from the grid. Power export is interrupted.
No fault message is displayed.
If the mains fault is present for less than 60 seconds,
power export automatically resumes within 10 minutes.
30
are displayed
Remedy
Wait until heat transfer is possible again.
Wait until the regeneration phase has been completed.
Note
After approx. 45 hours of operation, the fuel cell module
will briefly shut down for regeneration, in order to main-
tain the performance of the fuel cell module.
Switch on the energy manager: See page 18.
Please notify your heating contractor so that the service
can be carried out.
Please notify your heating contractor so that the service
can be carried out.
Please notify your heating contractor.
If a fault message is displayed, please notify your heat-
ing contractor: See chapter "System characteristics dur-
ing a mains fault".
Remedy
Proceed as described on page 24.
Remedy
Proceed as described on page 24.
Remedy
Unlock it: See page 19.
If the mains fault is present for more than 60 seconds,
the fuel cell module of the system shuts down.
Provided the mains fault is no longer present, power
generation by the system automatically resumes
24 hours after its last start. Should the same mains
fault lead to a further shutdown of the fuel cell module
within 7 consecutive days, there is a possibility of per-
manent mains instability.