Configuring Device As Udp Client To Connect To Udp Server - Multitech MultiConnect microCell User Manual

Hide thumbs Also See for MultiConnect microCell:
Table of Contents

Advertisement

CONFIGURING AND COMMUNICATING WITH YOUR DEVICE
7.
Accept incoming connection ID 1
Enter:
AT#SA=1
The device indicates a client successfully established a listener connection.
CONNECT
The device can send and receive data now.
Exit Data Mode and Close Connection
To exit data mode and close the socket:
1.
Enter the escape sequence:
+++
2.
To close Socket 1, enter:
AT#SH=1
3.
To close the data connection, enter:
Verizon:
AT#SGACT=3,0
Other Networks:
AT#SGACT=1,0
The device responds with OK.

Configuring Device as UDP Client to Connect to UDP Server

Configure and Connect the Device
To configure the device as a UDP client:
1.
Check signal strength.
Enter:
AT+CSQ
2.
Verify device is registered on the cellular network.
Enter:
AT+CEREG?
Should return:
+CEREG: 0,1 or +CEREG: 0,5
OK
3.
Configure socket parameters
Enter:
AT#SCFG=1,3,300,240,600,50
4.
Activate context one
Enter:
Verizon:
AT#SGACT=3,1
Other Networks:
AT#SGACT=1,1
5.
Create UDP connection to Server port
22
®
MultiConnect
microCell MTCM-LAT3 and -LSP3 User Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MultiConnect microCell and is the answer not in the manual?

This manual is also suitable for:

Mtcm-lat3Mtcm-lsp3