THIS MANUAL CONTAINS IMPORTANT SAFETY INFORMATION AND SHOULD ALWAYS BE AVAILABLE TO THOSE PERSONNEL OPERATING THIS UNIT. READ, UNDERSTAND AND RETAIN ALL INSTRUCTIONS BEFORE OPERATING THIS EQUIPMENT TO PREVENT INJURY OR EQUIPMENT DAMAGE. TWO STAGE/TWO CYLINDER DUPLEX AIR COMPRESSOR UNIT MODEL CADRSASP12 CADRSASP13 Form No. CQF3422 VER: 01 07/18/2017...
PARTS AND SUPPORT SERVICES Champion Compressor genuine parts, manufactured to design tolerances, are developed for optimum dependability – specifically for Champion compressor systems. Design and material innovations are the result of years of experience with hundreds of different compressor applications. Reliability in materials and quality assurance are incorporated in our genuine replacement parts.
Safety and Operation Precautions can result in injuries or equipment damage. However, Champion – A Gardner Denver Co., does not state as fact or does not mean to imply that the preceding list of Safety and Operating Precautions is all inclusive, and further that the observance of this list will prevent all...
Indicates immediate hazards which will result in severe injury or death. Indicates hazards or unsafe practice which could result in severe injury or death. Indicates hazards or unsafe practice which could result in damage to the Champion compressor or minor injury.
(60) months from date of installation or sixty-six (66) months from date of shipment by CHAMPION or CHAMPION distributor, whichever may occur first. Applies to the compressor pump only, excluding head valves. Valves, controls and accessories are warranted for the first year only.
TWO STAGE AIR COMPRESSOR - R15B PUMP DIMENSIONS ITEM R15B Base-Width 10” Bolt Down-Width 4-3/8” Bolt Down to Edge 5/8” Base to Crank Ctr 5-1/2” Overall Width 18” Overall Height 23-1/4” Bolt Down Hole Dia. 15/32” Base-Depth 7-1/2” Bolt Down Depth 5-3/4”...
Page 8
The vibro-isolator pads which came with the unit will need to be installed on the unit. Tanks bolted directly to a concrete floor without padding will not be warranted against cracking. Champion vibro- isolators must be used for extended warranty to apply to ASME air receivers.
Page 9
INSTALLATION (CONT’D) AIR LINE PIPING Connection to air system should be of the same size, or larger, than discharge pipe out of unit. The table gives recommended minimum pipe sizes. A union connection to the unit and water drop leg is recommended.
Page 11
INSTALLATION (CONT’D) INCOMING POWER – SEE FIGURE 2 NOTICE Upstream protection fusible disconnect or circuit breaker must be provided by installer. “LOCK OUT” OR “TAG OUT” ALL SOURCES OF POWER. 1. Connect wire for one incoming power line to L1. 2.
INSTALLATION (CONT’D) Wiring must be such that when viewing compressor from opposite shaft end, rotation of shaft is clockwise as shown by arrow on guard. Wrong direction rotation for any length of time will result in damage to compressor. GROUNDING INSTRUCTIONS This product should be connected to a grounded, metallic, permanent wiring system, or an equipment- grounding terminal or lead on the product.
Page 18
OPERATION CONT’D OIL MONITOR RESET KNOB UNSAFE LEVEL SAFE LEVEL C509-A (Ref. Drawing) OIL MONITOR. The oil monitor must be used in conjunction with the control panel (see wiring diagram page 9 for details). The oil monitor is installed on the outside of the air compressor crankcase with a port that allows oil to feed into it’s float bowl chamber and maintain the same level as in the crankcase.
GUIDE TO MAINTENANCE To obtain reliable and satisfactory service, this unit requires a consistent preventive maintenance schedule. Maintenance schedule pages are included in the back of this manual to aid in keeping the proper records. Before performing any maintenance function, switch main disconnect switch to "off" position to assure no power is entering unit.
EVERY 90 DAYS OR 500 HOURS MAINTENANCE Change crankcase oil. Use type and grade oil as specified in the section on "Compressor Oil Specifications". Check entire system for air leakage around fittings, connections, and gaskets, using soap solution and brush. Tighten nuts and capscrews as required.
GENERAL MAINTENANCE (Cont'd.) CENTRIFUGAL UNLOADER AND UNLOADER PRESSURE RELEASE VALVE: The centrifugal unloader is operated by two governor weights. It is totally enclosed and lubricated from the crankcase of the compressor. When compressor starts, the governor weights automatically open compressing the main spring, allowing the unloader pressure release valve to close. When the compressor stops, the main spring returns the governor weights to normal position opening the unloader pressure release valve and unloading the compressor.
“Emulsification of oil (white milky substance) indicates unsafe accumulation of moisture and may be evidence compressor is oversized for application. Failure to promptly consult your local distributor, or Champion Customer Service, can be grounds to deny warranty.” NOTES: 1. Normal break-in period of Champion air compressors is 25 hours.
TROUBLE SHOOTING CHART FOR COMPRESSOR Always disconnect unit from power supply and relieve all pressure from air tank before performing any maintenance. Failure to do so may result in equipment damage or injury. ALock Out" or "Tag Out" all power sources. Never operate unit without belt guard in place.
Page 24
Troubleshooting Chart (Cont’d Symptom Possible Cause(s) Corrective Action Air escapes from centrifugal unloader Centrifugal unloader release valve Clean or replace valve when unit is running dirty or detective. Air escapes from centrifugal unloader Check valve stuck in open position. Replace check valve. when unit is stopped.
Page 25
PARTS ILLUSTRATION MODEL: CADRSASP12 307CAD810-A (Ref. Drawing)
Page 36
DUPLEX CONTROL PANEL ENCLOSURE DIMENSIONS: L = 14.27” W = 10.81” H = 17.50” MOUNTING DIMENSIONS: L = 12.00” H = 16.75” MOUNTING FASTENER SIZE: 1/4" SIDE VIEW FRONT VIEW NOTICE · The duplex control panel will control two (2) 5HP compressors operating at 460V, 3phase, 60Hz. The panel will automatically start and stop the units as well as alternate the starting of units.
RECEIVER DRAIN TIMER OPERATION The Drain Timer is designed for trouble-free draining of un-wanted accumulations of condensate. The timer module initiates a drain cycle by energizing the valve coil that opens the valve and allows the condensate to drain. At the end of the cycle, the coil is de- energized and the valve is spring-returned to the closed position.
UNIT HAZARD DECAL LISTING PAGE DESCRIPTION PART NO. PRODUCT LIABILITY DECAL SHEET - MASTER P10157A Unit Pressure Setting NOT USED DANGER – Breathing Air DANGER – Drain Tank Daily WARNING – Pressure/Safety Valve NOT USED DANGER – Valve Maintenance DANGER – High Voltage WARNING –...
RECORD OF MAINTENANCE SERVICE Daily · DRAIN MOISTURE FROM TANK WEEKLY EVERY 3 MONTHS · CLEAN FILTER · INSPECT VALVE ASSEMBLIES · CLEAN COMPRESSOR ·TIGHTEN ALL FASTENERS · CHECK V-BELTS ·TEST PRESSURE RELIEF VALVE...