AURATON Libra SET Manual page 42

Hide thumbs Also See for Libra SET:
Table of Contents

Advertisement

26/10/21, 4:32 μ.μ.
NOTE:
If no button is pressed for 10 seconds while changing the configuration
settings, AURATON Libra R will return to the normal operating mode.
PWM operating mode
By changing the hysteresis settings (chapter "Configuration settings), we can turn on
the PWM operating mode. In this mode, AURATON Libra R cyclically turns on the
heating device in order to minimize temperature fluctuations. AURATON Libra R
checks the temperature rise times and the temperature drop times.
Knowing these values, AURATON Libra R turns on and off the heating device in
such cycles to keep the temperature as close as possible to the set value.
https://manuals.auraton.pl/manuals/auraton-libra-set-pl/
AURATON Libra SET - AURATON manuals
(Pulse-Width Modulation)
1 – Temperature
2 – Time
3 – Set temperature
4 – Room temperature
Introduction to programming
programming
Manual control
Anti-freeze temperature
Description of AURATON Fornax
Pairing AURATON Libra R of a weekly, wireless
temperature controller (transmitter) with AURATON
Fornax - a wireless controller for a heating or air-
conditioning device (receiver)
RESET AURATON Libra R
MASTER RESET AURATON Libra R
Configuration settings
PWM operating mode
Special situations
Unique features of AURATON Fornax
Additional remarks
Connection diagram of AURATON Fornax
Cleaning and maintenance
Technical data
Disposal of the device
To download
Weekly, wireless temperature controller with
AURATON Fornax heating or air conditioning
controller (set)
The description of AURATON Libra R
The first launch of AURATON Libra R.
42/50

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Libra SET and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents