Figure 66
2. Route the RF cables through the cable inlet.
Figure 67
Note: Leave the dust caps on unused connectors on FUs. If no dust caps are
3. Connect the first cable to the lower connector of the left most FU, and
then the next cable to upper connector. Proceed in the same way with
the other FUs. The order is shown in the figure below. Each cable must
be tightened to a torque of 25 Nm, using a torque wrench and a 32 mm
open-ended head.
54
All manuals and user guides at all-guides.com
RF Cable Inlet
RF Cable Routing
found, inform the person in charge that these are needed.