6. If the cable is of dual coaxial type, then leave 12 mm of the outer screen
and strip 15 mm of the insulation of each conductor as shown in the figure
below.
7. Strip 5 mm of the insulation from the ends of the inner conductors.
8. Prepare at least 25 mm of the screens by twisting them as shown in the
figure below.
9. Attach both the screens and two jumpers (thin copper wires) to a single
crimp terminal, as shown in the figure below.
Figure 49
10. Connect each wire to the terminal block of the OVP module, using a small
screwdriver (<2.5 mm) to open the terminal connectors. See relevant figure
below depending on the OVP variant used.