Ericsson RBS 3107 Installation Instruction page 45

Hide thumbs Also See for RBS 3107:
Table of Contents

Advertisement

Single coaxial cables
Two coaxial cables are connected to one connection block of an OVP
module.
To connect a coaxial cable to an Overvoltage Protection (OVP) module, do
the following:
Note: The instructions describe the connections to one connection block of
1. Ensure that the DF is not fastened in place, and that the space beneath it is
accessible. See Section 3.3 on page 10.
2. Remove the rubber sealing in the DF cable entry closest to the OVP
module to be used.
Note: If single coaxial cables are used, then two cable inlets are needed
3. Insert the cable gland and tighten it with a 20 mm open-ended wrench.
See 1 in the figure below.
4. Pass at least 170 mm of the cable through the cable. See 2 in the figure
below.
Figure 48
5. Strip 170 mm of the outer layer of insulation from the cable, using a wire
stripper. See figure below.
1/1531-COH 109 2073 Uen H 2006-11-06
All manuals and user guides at all-guides.com
an OVP module.
for connection to one connection block of an OVP module.
Cable Gland Attachment and Cable Routing
Procedure
41