10.3 PRINTER
The options below are available after selecting Other menu, provided the optional printer
is fitted in the system. (007950014100).
CLIMA-TECH PLUS/HD EVOLUTION: using the built-in printer allows to obtain a confirmation
of performing each phase. The following functionalities are available:
Repeat printing
User's data
Use Up and Down buttons to select the desired option. Confirm with ENTER.
10.3.1 Repeating the report
Press Repeat printing to print a copy of the confirmation for the last operation performed.
10.3.2 Personalizing report data
Select User's data to modify printout header. The header may contain 5 to 20 characters.
Repeat printing
User's data
Use Up and Down buttons to select the desired option. Confirm with ENTER.
The following options appear on the display:
Enter data
Magneti Marelli
You can change one line at a time. Select the line to be edited using Up and Down
buttons. Confirm with ENTER. The cursor appears in the first character's field.
Set the new confirmation printout header using Up and Down buttons.
See item Błąd! Nie można odnaleźć źródła odwołania. Błąd! Nie można odnaleźć źródła
odwołania.Edit
Press and hold Enter for 3 sec. to confirm editing of the line is finished.
After entering all lines press STOP/BACK to return.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Clima-Tech Plus and is the answer not in the manual?

Questions and answers

Thierry
February 8, 2025

Problème étalonnage code erreur ne peut plus étalonné

1 comments:
Mr. Anderson
February 11, 2025

Calibration performed by an unauthorized service station is considered an issue with the Magneti Marelli Clima-Tech Plus. This is not covered under the warranty and may result in additional costs for the client.

This answer is automatically generated

ROGERIO DUARTE RIBEIRO
April 10, 2025

Boa tarde, Gostaria de reseta sem o tempo de manutenção teria como fazer isso

User image 67f7de4aa46a1
1 comments:
Mr. Anderson
April 10, 2025

To reset the maintenance timer on a Magneti Marelli Clima-Tech Plus:

1. Navigate to the vacuum pump counter reset menu.
2. Press ENTER to confirm.
3. When the display shows "Hold ENTER button for 3 seconds! Counter reset," hold the ENTER button for 3 seconds.
4. Confirm the reset by pressing ENTER again.

This completes the maintenance timer reset.