Safety Devices - Magneti Marelli Clima-Tech Plus User Manual

Table of Contents

Advertisement

4.2.2
Refrigerant storage precautions
Do not allow mixing various types of refrigerants removed from A/C systems.
CLIMA TECH EVOLUTION is designed to support only R134a.
To avoid mixing various refrigerants, it is recommended to store them in separate cylinders.
Cylinders may not contain oil or other contaminants and the refrigerant they contain must
be clearly indicated.
4.2.3
Conditions for further usability of refrigerant
Knowing the origin and the age of the A/C system is very important for deciding about
further usability of refrigerant. A/C system repairs and maintenance greatly impact the
refrigerant quality.
If the system was not emptied correctly or not properly cleaned, the refrigerant and oil
may be highly contaminated. If you do nit know the history of the A/C system, recycle the
removed refrigerant in at least one cycle before it is reintroduced in the system.
If the operator is not certain how much contaminated the refrigerant is, it may be
checked using a special acidity and water content measurement set.
4.2.4
Recycling remarks
Replace the recycling system filter set regularly (see "Messages" section), to assure correct
operation of the device.
Refrigerant recycling should be carried out even if all parameters indicate that it is not
necessary.
4.2.5
General information
Before the refrigerant is introduced in the system, make sure the system was cleaned and
emptied.
All recommendations specified in this manual must be complied with to assure that the
system is not contaminated before filling it with the refrigerant.
Regularly clean and maintain the device if it is frequently in contact with contaminants; it
is important that the contamination remaining after the last interference in the system is
not transferred to the new refrigerant

4.3 Safety devices

CLIMA TECH EVOLUTION is equipped with the following safety devices:
• Pressure sensor: switches off the compressor if excessive pressure builds up.
• Pressure relief valves
• Main switch: allows to disconnect the power supply if it is necessary to interfere in the
device.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Clima-Tech Plus and is the answer not in the manual?

Questions and answers

Thierry
February 8, 2025

Problème étalonnage code erreur ne peut plus étalonné

1 comments:
Mr. Anderson
February 11, 2025

Calibration performed by an unauthorized service station is considered an issue with the Magneti Marelli Clima-Tech Plus. This is not covered under the warranty and may result in additional costs for the client.

This answer is automatically generated

ROGERIO DUARTE RIBEIRO
April 10, 2025

Boa tarde, Gostaria de reseta sem o tempo de manutenção teria como fazer isso

User image 67f7de4aa46a1
1 comments:
Mr. Anderson
April 10, 2025

To reset the maintenance timer on a Magneti Marelli Clima-Tech Plus:

1. Navigate to the vacuum pump counter reset menu.
2. Press ENTER to confirm.
3. When the display shows "Hold ENTER button for 3 seconds! Counter reset," hold the ENTER button for 3 seconds.
4. Confirm the reset by pressing ENTER again.

This completes the maintenance timer reset.