Vacuum time
min
20
A 20-minute vacuum phase will be suggested.
Use UP-DOWN buttons to select the desired value. Confirm by pressing ENTER.
System leaktightness
control min.
A 4-minute system leak test will be suggested at the end of vacuum phase. .
Use UP-DOWN buttons to select the desired value. Confirm by pressing ENTER.
Inject oil-UV? Yes
Select using UP-DOWN buttons. Confirm by pressing ENTER.
If NO option is selected, the station will suggest going into filling phase.
If YES option is selected, the following message is displayed:
Manual Oil-UV
Synchro. Oil-Uv
Select using UP-DOWN buttons. Confirm by pressing ENTER.
If synchronized oil-UV feeding option is selected, the station will suggest switching into
Synchronic oil-UV feeding phase.
See 9.5.2 Synchronic oil-UV feeding.
If Manual oil-UV option is selected, the following message is displayed:
Specify refrigerant weight
Refrig.
g.
Use UP-DOWN buttons to enter refrigerant quantity. Confirm by pressing ENTER.
Start operation?
Confirm by pressing ENTER.
Manual Oil-UV
Synchro. Oil-Uv □
Use UP-DOWN buttons to select Manual Oil-UV. Confirm by pressing ENTER.
After the vacuum phase the station will stop to allow manual feeding of oil -UV.
4
No
700
8.5 Synchronic oil-UV feeding.
8.5.1
Manual oil-UV feeding.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Clima-Tech Plus and is the answer not in the manual?

Questions and answers

Thierry
February 8, 2025

Problème étalonnage code erreur ne peut plus étalonné

1 comments:
Mr. Anderson
February 11, 2025

Calibration performed by an unauthorized service station is considered an issue with the Magneti Marelli Clima-Tech Plus. This is not covered under the warranty and may result in additional costs for the client.

This answer is automatically generated

ROGERIO DUARTE RIBEIRO
April 10, 2025

Boa tarde, Gostaria de reseta sem o tempo de manutenção teria como fazer isso

User image 67f7de4aa46a1
1 comments:
Mr. Anderson
April 10, 2025

To reset the maintenance timer on a Magneti Marelli Clima-Tech Plus:

1. Navigate to the vacuum pump counter reset menu.
2. Press ENTER to confirm.
3. When the display shows "Hold ENTER button for 3 seconds! Counter reset," hold the ENTER button for 3 seconds.
4. Confirm the reset by pressing ENTER again.

This completes the maintenance timer reset.

This answer is automatically generated