WARNING! Maximum pressure
in the internal cylinder
Maximum pressure was reached in the internal tank. Wait approx. 30 minutes before
restarting the refrigerant recovery function. If this does not eliminate the problem, contact
Magneti Marelli technical support.
WARNING! Internal cylinder
is full
Maximum permitted quantity of refrigerant in the internal cylinder was reached. This value
cannot be exceeded in any circumstances.
WARNING! Pressure in
the A/C system
Appears at the beginning of the vacuum phase, if pressure is detected in the A/C system.
The device starts the recovery phase.
A/C-not tight! Continue?
mB
XXX
Vehicle A/C system is not tight. This message appears if the station detects a pressure
growth in the system during vacuum leak test. Repair the A/C system.
Select ENTER to continue. Select STOP/RETURN to return to standby mode
Insufficient vacuum.
Continue?
mB
XXX
This message appears after 10 minutes of vacuum build-up if the pressure in the A/C
system is not lower than 100 mBar.
Select ENTER to continue with the vacuum phase. Select STOP/RETURN to return to standby
mode
WARNING!
Insufficient vacuum
Excessive pressure during pressure check before oil or contrast injection. This phase is only
run in systems in which vacuum was achieved.
Select ENTER to continue. Select STOP/RETURN to return to standby mode
Insufficient refrigerant quantity!
Add refrigerant!
Too little refrigerant in the internal tank. Select ENTER to go to the phase of refrigerant filling
from the external cylinder. Select STOP/RETURN to go to the next step.
External cylinder empty
or valve is closed!
Please check!
6 MESSAGES

6.1 Error messages

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Clima-Tech Plus and is the answer not in the manual?

Questions and answers

Thierry
February 8, 2025

Problème étalonnage code erreur ne peut plus étalonné

1 comments:
Mr. Anderson
February 11, 2025

Calibration performed by an unauthorized service station is considered an issue with the Magneti Marelli Clima-Tech Plus. This is not covered under the warranty and may result in additional costs for the client.

This answer is automatically generated

ROGERIO DUARTE RIBEIRO
April 10, 2025

Boa tarde, Gostaria de reseta sem o tempo de manutenção teria como fazer isso

User image 67f7de4aa46a1
1 comments:
Mr. Anderson
April 10, 2025

To reset the maintenance timer on a Magneti Marelli Clima-Tech Plus:

1. Navigate to the vacuum pump counter reset menu.
2. Press ENTER to confirm.
3. When the display shows "Hold ENTER button for 3 seconds! Counter reset," hold the ENTER button for 3 seconds.
4. Confirm the reset by pressing ENTER again.

This completes the maintenance timer reset.