should not be used to support the full
weight of the dehumidifier. When
carrying the unit, it should be kept
upright and suifficiently supported from
its base.
The handle should not be used if there
•
are any signs of damage to its fixings.
The appliance must be placed in a room
•
without sources of ignition (for example:
open
flames,
appliance or an operating electric
heater).
R290 refrigerant gas complies with
•
European environmental directives.
R290 has a low GWP (Global Warming
•
Potential) of 3.
The CD12LE and CD12LEB contains
•
about 50g of R290 refrigerant gas.
The CD20LE and CD20LEB contains
•
about 80g of R290 refrigerant gas.
Do not use or store the appliance in an
•
unventilated space with an area smaller
2
than 4m
per unit.
If the appliance is installed, used or
•
stored in an unventilated room, the
room must be such as to prevent
stagnation
of
refrigerant gas as there could be a
danger of fire or explosion should the
refrigerant come into contact with
electric heaters, stoves or other sources
of ignition.
Refrigerant gas may be odourless.
•
Do not use the product and contact the
•
retailer for advice, if damage has
occurred to the unit which may have
compromised the refrigerant system.
Any repairs or maintenance must only
•
be carried out on the unit by a suitably
qualified engineer. Before opening and
servicing
the
engineer must be in possession of a
copy of the manufacturer's service
manual and must follow the safety
information contained within it to ensure
an
operating
possible
leaks
unit
the
authorized
all hazards are minimized.
The refrigerant system should not be
•
perforated or punctured.
Do not place the unit next to heat
•
sources (e.g. electrical fires, fireplaces,
etc.)
Avoid mishandling the dehumidifier.
•
Dropping, throwing the unit can cause
damage to its internals and increases
gas
the risks of operating it.
Do not store or use gasoline, petrol,
•
paint, solvents or other flammable
vapours or liquids in the vicinity of this
dehumidifier or any other appliance.
This dehumidifier must not be used in
•
spaces
concentration of gases, solvent or other
volatile organic compounds; in very
dusty environments; in any domestic,
commercial or industrial environment
where the air composition is flammable.
ENERGY SAVING AND UNIT SAFETY
PROTECTION TIPS
•
Do not cover or restrict the airflow from
of
the outlet or inlet grills. Do not operate
and follow troubleshoot procedure if the
self-opening louvers do not open on
power on.
•
For
maximum
minimum distance from a wall or objects
should be 20 cm
•
Keep the filters or grills of the unit clean.
Under normal conditions, filters or grills
should only need cleaning once every
three weeks (approximately).
•
Since the filters remove airborne
particles,
maybe necessary, depending on the air
quality.
optional HEPA filter and wash the mesh
filters with hot soapy water and dry
them before placing them back in the
unit.