Siemens SIMOTICS S-1FT2 Operating Instructions Manual page 82

Synchronous motors
Hide thumbs Also See for SIMOTICS S-1FT2:
Table of Contents

Advertisement

Faults and their rectification
Table 9- 2
"Fault causes and remedial measures" key table
No.
Fault cause
A
Overload
B
Interruption of a phase in the
supply cable / motor winding
C
Interrupted phase in the feeder
cable after switching on
D
Converter output voltage too
high, frequency too low
F
Winding short-circuit or phase
short-circuit in stator winding
I
Heat dissipation impeded by dirt
Cooling air inlet/outlet is blocked
by foreign bodies
J
Insufficient shielding for motor
and/or encoder cable
K
Excessive drive controller gain
L
Rotating parts are grinding
Foreign bodies inside the motor
Bearing damage
M
Rotor not balanced
N
Rotor out of true, shaft bent
O
Poor alignment
P
Coupled machine not balanced
Q
Shocks from coupled machine
R
Fault originating from the gear-
box
If the fault still cannot be resolved after taking the measures stated above, please contact the
manufacturer or the Siemens Service Center.
80
Remedial measures
Reduce load
Check the frequency converter and supply cables, measure the winding re-
sistances and insulation resistances, repair after consultation with manufacturer
Check the frequency converter, supply cables and the winding resistances
Check the settings on the frequency converter, perform automatic motor identi-
fication
Measure the winding resistances and insulation resistances, repair after consul-
tation with the manufacturer, if required, replace the motor
Clean the surface of the drives and ensure that the cooling air can flow in and
out unimpeded
Remove the reason for the blocking and ensure that the cooling air can flow in
and out unimpeded
Check the shielding and grounding
Adjust the controller
Determine cause and adjust parts
Replace the motor
Replace the motor
Replace the motor
Consult the manufacturer
Align motor set, check coupling
Re-balance coupled machine
Check coupled machine
Adjust/repair gearbox
SIMOTICS S-1FT2 synchronous motors for SINAMICS S120
Operating Instructions, 07/2021, A5E50610821B AB

Advertisement

Table of Contents
loading