Siemens SIMOTICS S-1FT2 Operating Instructions Manual page 74

Synchronous motors
Hide thumbs Also See for SIMOTICS S-1FT2:
Table of Contents

Advertisement

Commissioning
7.1 Checklists for commissioning
Table 7- 2
Have all touch protection measures for moving and live parts been fitted and are they
functional?
Has the motor been correctly mounted and aligned?
Can you rotate the rotor without it touching the stator?
Have all fastening screws, fastening elements, and electrical connections been tight-
ened with the prescribed torques and properly attached?
Do the operating conditions correspond to the data specified on the rating plate?
Do the output elements have the correct setting conditions according to type?
Examples:
Table 7- 3
Has the motor been connected so that it rotates in the specified direction?
Have the minimum insulation resistance values been maintained?
Have the grounding and equipotential bonding connections been correctly estab-
lished?
Is the specified limit speed n
Table 7- 4
Has it been ensured that speeds higher than the maximum speed n
reached?
Have all supplementary motor monitoring devices been correctly connected and are
they working properly?
Table 7- 5
Natural cooling
Have you adapted the torque and power of the motor to the ambient conditions?
You will find information on the derating in the configuration manual.
Observe the information provided in the converter operating instructions.
Table 7- 6
Is the brake open when the operating voltage is applied?
Does the brake open and close correctly?
72
Checklist (2) - checks regarding the mechanical system
Have the couplings been aligned and balanced?
Has the belt drive tension been correctly adjusted?
Have the gear tooth flank and gear tooth tip play as well as radial play been correct-
ly adjusted for geared outputs?
Checklist (3) - checks regarding the electrical system
max
Checklist (4) - Monitoring equipment checks
Checklist (5) - Cooling system checks
Checklist (6) - Checks regarding the optional brake
Check
Check
maintained during the operation on the converter?
Check
Check
Check
SIMOTICS S-1FT2 synchronous motors for SINAMICS S120
Operating Instructions, 07/2021, A5E50610821B AB
cannot be
max
OK
OK
OK
OK
OK