Figure 001-9: Actuator and Compensation Microswitch

Five different settings can be registered:
Position
Microswitch position
1
In front of the first cam
2
On the first cam
3
Between the two cams
4
On the second cam
5
Behind the second cam

Table 001-1: Switch Cam Settings

Three volume areas can be measured for the grind amount; see Figure 001-
10. They represent the selectable volume areas on the machine; see Figure
001-11.

Figure 001-10: Measurable Volume Areas

Figure 001-11: Selectable Volume Areas

If the measure quantity varies from the set quantity, then the grinding time will
be increased or decreased by approximately 0.2 seconds as appropriate
during the next grinding cycle. Because the maximum ground quantity
Technical Information
1 Brew unit actuator
2 Grind amount compensation microswitch
Switching process
Off
Off, on
Off, on, off
Off, on, off, on
Off, on, off, on, off
1, 2, 3 Measurable volume areas 1, 2 and 3
1, 2, 3 Selectable volume areas 1, 2 and 3