Guidance and manufacturer's declaration – electromagnetic emissions
Voltage dips, short
interruptions and
voltage variations on
power supply input
lines IEC 61000-4-11
Power frequency (50
/ 60Hz) magnetic eld
IEC 61000-4-8
U T is the a.c. mains voltage prior to the application of the test level.
Guidance and manufacturer's declaration – electromagnetic immunity
IndiGo is intended for use in the electromagnetic environment speci ed below. The customer or the user
of IndiGo should ensure that it is used in such an environment.
Immunity
IEC 60601
test
test level
Conducted
3V rms
RF
150kHz to
IEC 61000-
80MHz 3V/m
4-6 Radiated
80MHz to
RF IEC
2.5GHz
61000-4-3
At 80MHz and 800MHz, the higher frequency range applies.
These guidelines may not apply in all situations. Electromagnetic propagation
is affected by absorption and re ection from structures, objects and people.
20
70% of input
voltage for
70% U
T
500ms
(30% dip in U T )
for 25 cycles
40% of input
40% U T
voltage for
(60% dip in U T )
100ms
for 5 cycles
<5% U T
<5% of input
(>95% dip in U T )
voltage for
for 0.5 cycle
10ms
<5% U T
(>95% dip in U T )
<5% of input
for 5 sec.
voltage for
5000ms
3A/m
3A/m
Compliance
level
3V
3V/m
Mains power quality should be that of a
typical commercial or hospital environment.
If the user of IndiGo requires continued
operation during mains power interruptions,
it is recommended that IndiGo be powered
from an uninterruptible power supply or
battery.
Power frequency magnetic elds should
be at levels characteristic of a typical
location in a typical commercial or hospital
environment.
Electromagnetic environment -guidance
Portable and mobile RF communications equipment should
be used no closer to any part of IndiGo, including cables,
than the recommended separation distance calculated
from the equation applicable to the frequency of the
transmitter. Recommended separation distance
Where
is the maximum output power rating of the
P
transmitter in watts (W) according to the transmitter
manufacturer and d is the recommended separation in
meters (m). Field strengths from xed RF transmitters, as
determined by an electromagnetic site survey,
less than the compliance level in each frequency range.
Interference may occur in the vicinity of equipment marked
with the following symbol:
a
should be
b