Maintenance Every Year; Check, Adjust The Valve Clearance - Fayat Bomag BP 20/50 Operating Instructions Manual

Table of Contents

Advertisement

Maintenance every year

6.17 Check, adjust the valve
clearance
Caution
!
We recommend to have this work carried out
by trained personnel or our after sales service.
Check and adjust only when the engine is cold
(approx. 20 °C (68 °F)).
Fig. 59
Loosen the screws (1) (Fig. 59) and take off
l
the valve cover (2) with gasket (3).
Fig. 60
Set the piston to top dead centre position of
l
the compression stroke.
For this purpose align the alignment mark (1)
l
(Fig. 60) on the starter disc to the top bore (2).
BP 20/50, BP 25/50
Check the valve clearance
Valve clearance:
Intake valve = 0.15 mm (0.006 in)
Exhaust valve = 0.20 mm (0.008 in)
Fig. 61
Check the valve clearance with a feeler gauge
l
on both valves (Fig. 61).
Adjust the valve clearance
Fig. 62
Hold hexagon nut (4) (Fig. 62) on the rocker le-
l
ver and loosen counter nut (3).
Adjust hexagon nut on the rocker arm so that
l
the feeler gauge fits between rocker arm (2)
and valve shaft (1) with noticeable resistance
after retightening counter nut.
Install the valve cover with a new gasket and
l
tighten the screws evenly.
BOMAG
Maintenance every year
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bomag bp 25/50

Table of Contents