6.1 Service items
• Filters should be replaced at six month intervals for Commercial HydroTaps, and 12 month intervals for
Residential HydroTaps.
• CO2 regulator washers should be replaced annually.
6.2 Trouble shooting table
Fault
Fault name
code
000
Power Board Fault
001
Interface Fault
004
Water Leak, Isolate Mains
005
Compressor OverRun
006
Water Supply Failure
007
Hot Sensor Open
008
Hot Sensor Closed
009
Cold Sensor Open
010
Cold Sensor Closed
011
Flood Sensor Open
012
Condenser Sensor Closed
013
Condenser Sensor Open
014
Heater Fuse/Driver Fault
015
Heater Driver Fault
016
Compr Driver Fault
017
Hot Sensor Degraded
018
Condenser Overtemp
019
A DC Pump is faulty
020
Steam too cool
021
Steam Sensor Open
022
Steam Sensor Closed
023
Over Steamed
024
Hot Tank Overfilled
025
Comp Fuse/Driver Fault
027
Boil dry protection
• Call Zip for Advice and assistance (see contact details page 111).
806834 v1.02 07.21 G5 Online install instructions and user guide
Section 6 Service and Trouble shooting
Water detected in the unit due to tank overfill or
Compressor has been running continuously for an extended
Temperature of condenser has exceeded its limit
Heating protection device has activated
Fault trigger
Internal communication fault
Internal communication fault
internal / external leakage.
time period
Water not detected by unit
Internal sensor fault
Internal sensor fault
Internal sensor fault
Internal sensor fault
Internal sensor fault
Internal sensor fault
Internal sensor fault
Internal component fault
Internal component fault
Internal component fault
Internal sensor fault
Internal component fault
Boiling calibration error
Internal sensor fault
Internal sensor fault
Excess steam detected
Hot tank has over filled
Internal component fault
67
Need help?
Do you have a question about the HydroTap G5 BCS and is the answer not in the manual?