10.6.3 Parameter 3. DISPL

3
dISPL
Set the update cycle of display. The update cycle affects the life duration of battery. Even if "off"
is set and the display disappears, the information such as parameter and total value will not be
lost and the flow rate will be surely calculated.
Selectable range: FASt - 1 SEC - 3 SEC - 15 SEC - 30 SEC - OFF (standard setting: 1sec)
3.1
UPdAt
If you select "OFF", the display will be automatically turned OFF in 30 seconds after the final
operation, however, if you touch any key, the display will be turned ON again.
The bar chart display of instantaneous flow rate can be ON/OFF.
3.2
GrAPH
EnAbLE (enable): ON / dISAbLE (disable): Off
The range span of bar chart of instantaneous flow rate can be set. This display divides the
range span 0 to 100% into ten.
3.3
SPAn
Settable range: 0000.001 - 99,999
The lighting time of backlight can be set. If the lighting time becomes long, it affects the life
3.4
LIGHt
duration of battery.
Settable range: 0 to 99 sec (if you select 0, the backlight does not light up)

10.6.4 Parameter 4. METER

4
MEtEr
4.1
UnIt
The unit of meter coefficient can be set.
The meter coefficient can be set.
4.2
M.FACt
Settable range: 0.00001 to 99999999
The decimal point set by "4.3 dECS" decimal point position of meter coefficient is displayed.
The decimal point position of "4.2 M.FACt" meter coefficient can be selected from the following.
4.3
dECS
Settable range: 0 - 1 - 2 - 3 - 4 - 5 (0 has no decimal point)
26
NOTE: If the application does not require the high-speed display update cycle, it is
recommended to set the update cycle low.
NOTE: The decimal point set by decimal point position of instantaneous flow rate of "2.2
dECS" is displayed.